CANNON 9724-T75 Asphalt Institute Vacuum Viscometer with Holder, Size 800R, CALIBRATED
CANNON 9724-T75 Asphalt Institute Vacuum Viscometer with Holder
AIVC-RO-800R Calibrated ROOFING w/Round Holder
SKU# 9724-T75
Cannon Instruments
Overview: Asphalt Institute Vacuum Viscometer, size 800R roofing design, with attached holder, CALIBRATED
The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in).
Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a certificate of calibration and instruction sheet.
Holder is sold separately. For holder, see 9726-N15.
Specification
Method: ASTM D2171
Asphalt Institute Vacuum Viscometers
| Catalog Number | Size | Approximate Constant (poise/sec at 300 mm Hg) |
Viscosity Range (poise) |
||||
|---|---|---|---|---|---|---|---|
| without holder | with holder* | Bulb B | Bulb C | Bulb D | Low | High | |
| 9724-R50 | 9724-T50 | 25 | 2.0 | 1.0 | 0.7 | 42 | 800 |
| 9724-R55 | 9724-T55 | 50 | 8.0 | 4.0 | 3.0 | 180 | 3200 |
| 9724-R60 | 9724-T60 | 100 | 32 | 16 | 10 | 600 | 12800 |
| 9724-R65 | 9724-T65 | 200 | 128 | 64 | 40 | 2400 | 52000 |
| 9724-R70 | 9724-T70 | 400R | 500 | 250 | 160 | 9600 | 1400000 |
| 9724-R75 | 9724-T75 | 800R | 2000 | 1000 | 640 | 38000 | 5800000 |
*Round holder is compatible with a 51 mm (2 in) diameter port
A Cannon Asphalt Institute Vacuum Viscometer is a glass capillary viscometer used to measure the viscosity of highly viscous materials like asphalt, in accordance with ASTM D2171. It operates under a vacuum and requires a liquid bath for temperature control, with models like the AIVC-RO-400R having a minimum sample volume of 3 mL and a recommended bath depth of 180 mm. These viscometers are calibrated and come with a certificate and instructions for use in laboratory settings.
- Purpose: Measures the viscosity of highly viscous materials, such as asphalt cement, bitumen, and other high-viscosity fluids.
- Standard: Complies with the ASTM D2171 standard for vacuum viscosity testing.
- Operation: Uses a vacuum to draw the sample up through a capillary tube for timed testing. A liquid bath is required to control the temperature.
‘
‘
‘
CV. Andalan Prima Sejahtera Perumahan Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 Bekasi Utara, Kota Bekasi, Jawa Barat 17122 Telepon : 021-29253187, 021-29253186, 021-29253184 No. WA : +62 812-9311-3644, +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 Email : andalanps2@gmail.com, sales@cvaps.co.id Website : cvaps.co.id