CANNON 9724-R50 Asphalt Institute Vacuum Viscometer without Holder, Size 25, CALIBRATED
CANNON 9724-R50 Asphalt Institute Vacuum Viscometer without Holder
AIVC- 25 Calibrated
SKU# 9724-R50
Cannon Instruments
Asphalt Institute Vacuum Viscometer, size 25, CALIBRATED
The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in).
Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a certificate of calibration and instruction sheet.
Holder is sold separately. For holder, see 9726-N15.
Specification
Method: ASTM D2171
Asphalt Institute Vacuum Viscometers
| Catalog Number | Size | Approximate Constant (poise/sec at 300 mm Hg) |
Viscosity Range (poise) |
||||
|---|---|---|---|---|---|---|---|
| without holder | with holder* | Bulb B | Bulb C | Bulb D | Low | High | |
| 9724-R50 | 9724-T50 | 25 | 2.0 | 1.0 | 0.7 | 42 | 800 |
| 9724-R55 | 9724-T55 | 50 | 8.0 | 4.0 | 3.0 | 180 | 3200 |
| 9724-R60 | 9724-T60 | 100 | 32 | 16 | 10 | 600 | 12800 |
| 9724-R65 | 9724-T65 | 200 | 128 | 64 | 40 | 2400 | 52000 |
| 9724-R70 | 9724-T70 | 400R | 500 | 250 | 160 | 9600 | 1400000 |
| 9724-R75 | 9724-T75 | 800R | 2000 | 1000 | 640 | 38000 | 5800000 |
*Round holder is compatible with a 51 mm (2 in) diameter port
A Cannon Asphalt Institute Vacuum Viscometer is a glass capillary viscometer used to measure the viscosity of highly viscous materials like asphalt, in accordance with ASTM D2171. It operates under a vacuum and requires a liquid bath for temperature control, with models like the AIVC-RO-400R having a minimum sample volume of 3 mL and a recommended bath depth of 180 mm. These viscometers are calibrated and come with a certificate and instructions for use in laboratory settings.
- Purpose: Measures the viscosity of highly viscous materials, such as asphalt cement, bitumen, and other high-viscosity fluids.
- Standard: Complies with the ASTM D2171 standard for vacuum viscosity testing.
- Operation: Uses a vacuum to draw the sample up through a capillary tube for timed testing. A liquid bath is required to control the temperature.
‘
‘
‘
CV. Andalan Prima Sejahtera Perumahan Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 Bekasi Utara, Kota Bekasi, Jawa Barat 17122 Telepon : 021-29253187, 021-29253186, 021-29253184 No. WA : +62 812-9311-3644, +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 Email : andalanps2@gmail.com, sales@cvaps.co.id Website : cvaps.co.id