CANNON 9724-T60 Asphalt Institute Vacuum Viscometer with Holder, Size 100, CALIBRATED

Rp111.00

CANNON 9724-T60 Asphalt Institute Vacuum Viscometer with Holder, Size 100, CALIBRATED

CANNON 9724-T60 Asphalt Institute Vacuum Viscometer with Holder

 

AIVC-RO- 100 Calibrated w/Round Holder
SKU# 9724-T60
Cannon Instruments
Overview: Asphalt Institute Vacuum Viscometer, size 50, with attached holder, CALIBRATED

 

The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in).

Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a certificate of calibration and instruction sheet.
Holder is sold separately. For holder, see 9726-N15.

 

Specification

Method: ASTM D2171

 

Asphalt Institute Vacuum Viscometers

Catalog Number Size Approximate Constant
(poise/sec at 300 mm Hg)
Viscosity Range
(poise)
without holder with holder* Bulb B Bulb C Bulb D Low High
9724-R50 9724-T50 25 2.0 1.0 0.7 42 800
9724-R55 9724-T55 50 8.0 4.0 3.0 180 3200
9724-R60 9724-T60 100 32 16 10 600 12800
9724-R65 9724-T65 200 128 64 40 2400 52000
9724-R70 9724-T70 400R 500 250 160 9600 1400000
9724-R75 9724-T75 800R 2000 1000 640 38000 5800000

*Round holder is compatible with a 51 mm (2 in) diameter port

A Cannon Asphalt Institute Vacuum Viscometer is a glass capillary viscometer used to measure the viscosity of highly viscous materials like asphalt, in accordance with ASTM D2171. It operates under a vacuum and requires a liquid bath for temperature control, with models like the AIVC-RO-400R having a minimum sample volume of 3 mL and a recommended bath depth of 180 mm. These viscometers are calibrated and come with a certificate and instructions for use in laboratory settings.

Key features and specifications
  • Purpose: Measures the viscosity of highly viscous materials, such as asphalt cement, bitumen, and other high-viscosity fluids.
  • Standard: Complies with the ASTM D2171 standard for vacuum viscosity testing.
  • Operation: Uses a vacuum to draw the sample up through a capillary tube for timed testing. A liquid bath is required to control the temperature.

CV. Andalan Prima Sejahtera 
Perumahan Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 
Bekasi Utara, Kota Bekasi, Jawa Barat 17122 
Telepon  : 021-29253187, 021-29253186, 021-29253184 
No. WA   : +62 812-9311-3644, +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 
Email    : andalanps2@gmail.com, sales@cvaps.co.id 
Website  : cvaps.co.id