HYDRANAL – Titrant 5, titrating agent for volumetric two-component Karl Fischer titration (methanol-based).

34801 HYDRANAL – Titrant 5 Capacity 1 Liter, Honeywell Fluka

34801 HYDRANAL – Titrant 5 Capacity 1 Liter

 

34801 Fluka
HYDRANAL – Titrant 5
Titrating agent for volumetric two-component Karl Fischer titration (methanol-based)
Synonym(s)
Karl Fischer reagent

 

Specifications

Property Value
suitability (for KF-titration) test passed
titer (water equivalent) 4.90 – 5.10 mg/ml

Properties

Property Value
Boiling Point/Range 65 °C (1.013 hPa)
Color Brown
Density 0.850 g/cm3 (20 °C)
Flashpoint 11 °C
Form Liquid
Grade Volumetric Two-Component KF Titration
Incompatible Materials Oxidizing agents, Acid chlorides, Acid anhydrides, Reducing agents, Acids
Lower Explosion Limit 5.5 %(V)
Melting Point/Range -98 °C
Partition Coefficient No data available
Solubility in Water Completely miscible
Upper Explosion Limit 31 %(V)
Vapor Density No data available
Vapor Pressure 128 hPa (20 °C)
Viscosity No data available
pH-Value Neutral
Product Line Hydranal™
Storage Temperature Ambient

HYDRANAL™ – Titrant 5

HYDRANAL™ – Titrant 5 is a reagent used in Karl Fischer titration to determine the water content in a sample. This reagent contains iodine dissolved in alcohol, along with sulfur dioxide and imidazole in a solvent solution. More specifically, Titrant 5 is a volumetric two-component titration reagent, meaning it is used in combination with a compatible Karl Fischer solvent.

Karl Fischer Titration:

An analytical method used to determine the water content in various types of samples.

Composition of Titrant 5:

Titrant 5 contains iodine dissolved in alcohol, as well as sulfur dioxide and imidazole in a solvent.

Two-Component Reagent System:

HYDRANAL™ – Titrant 5 is part of a two-component titration system, which requires a separate solvent reagent (e.g., HYDRANAL™ – Solvent) to complete the titration process.

Solvents:

The solvents used in the HYDRANAL™ system can include:

  • Methanol (for standard reagents)

  • Ethanol (for E-type reagents)
    The choice of solvent depends on the type of sample being analyzed.

Applications:

HYDRANAL™ – Titrant 5 is widely used in analytical testing across industries such as chemicals, pharmaceuticals, and food, to ensure product quality and compliance.

CV. Andalan Prima Sejahtera Perumahan 
Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 
Bekasi Utara, Kota Bekasi, Jawa Barat 17122 
Telepon  : 021-29253187, 021-29253186, 021-29253184 
No. WA   : +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 
Email    : andalan123@gmail.com, sales@cvaps.co.id 
Website  : cvaps.co.id
Review Your Cart
0
Add Coupon Code
Subtotal