34800 HYDRANAL – Solvent Capacity 1 Liter, Honeywell Fluka
34800 HYDRANAL – Solvent Capacity 1 Liter
34800 Fluka
HYDRANAL – Solvent
Medium for volumetric two-component Karl Fischer titration (methanol-based)
Synonym(s)
Karl Fischer medium
Specifications
Property | Value |
---|---|
suitability (for KF-titration) | test passed |
Properties
Property | Value |
---|---|
Autoignition Temperature | Not auto-flammable |
Boiling Point/Range | 64-65 °C (Methanol) |
Color | Colorless |
Density | 0.890 g/cm3 (20 °C) |
Flashpoint | 11 °C |
Form | Liquid |
Grade | Volumetric Two-Component KF Titration |
Incompatible Materials | Oxidizing agents, Acids, Acid chlorides, Acid anhydrides, Reducing agents, Alkali metals |
Lower Explosion Limit | 5.5 %(V) |
Melting Point/Range | -98 °C (Methanol) |
Partition Coefficient | -0.71 |
Solubility in Water | Completely miscible |
Upper Explosion Limit | 31 %(V) |
Vapor Pressure | 171 hPa (20 °C) |
Viscosity | Not determined |
pH-Value | 5.5-6.5 |
Product Line | Hydranal™ |
Storage Temperature | Ambient |
HYDRANAL™ – Solvent
HYDRANAL™ – Solvent is an alcohol-based solution containing sulfur dioxide and imidazole, used as the solvent component in Karl Fischer titration, particularly in two-component volumetric methods. There are two main types of HYDRANAL solvents: one based on methanol (for standard reagents) and the other based on ethanol (for E-type reagents).
Karl Fischer Titration:
HYDRANAL-Solvent is part of the Karl Fischer titration system, a widely accepted standard method for determining water content in a wide variety of samples.
Components:
This solvent contains sulfur dioxide and imidazole, which work together to react with the water present in the sample.
Types of Solvent:
There are two types of HYDRANAL solvents, distinguished by the type of alcohol used:
-
Methanol-based (for use with standard titrants)
-
Ethanol-based (for use with E-type titrants)
The choice of solvent depends on the titrant type and the nature of the sample being tested.
Function:
HYDRANAL solvent serves to:
-
Dissolve the sample, and
-
Facilitate the reaction between the water in the sample and the titration reagent (usually iodine)
to achieve a precise titration endpoint.
Adaptation:
Other HYDRANAL solvent variants, with different solvent mixtures, are available to meet the specific requirements of diverse sample types.
‘
‘
CV. Andalan Prima Sejahtera Perumahan Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 Bekasi Utara, Kota Bekasi, Jawa Barat 17122 Telepon : 021-29253187, 021-29253186, 021-29253184 No. WA : +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 Email : andalan123@gmail.com, sales@cvaps.co.id Website : cvaps.co.id