34801 HYDRANAL – Titrant 5 Capacity 1 Liter, Honeywell Fluka

Rp2,850,000.00

HYDRANAL – Titrant 5, titrating agent for volumetric two-component Karl Fischer titration (methanol-based).

34801 HYDRANAL – Titrant 5 Capacity 1 Liter, Honeywell Fluka

34801 HYDRANAL – Titrant 5 Capacity 1 Liter

 

34801 Fluka
HYDRANAL – Titrant 5
Titrating agent for volumetric two-component Karl Fischer titration (methanol-based)
Synonym(s)
Karl Fischer reagent

 

Specifications

Property Value
suitability (for KF-titration) test passed
titer (water equivalent) 4.90 – 5.10 mg/ml

Properties

Property Value
Boiling Point/Range 65 °C (1.013 hPa)
Color Brown
Density 0.850 g/cm3 (20 °C)
Flashpoint 11 °C
Form Liquid
Grade Volumetric Two-Component KF Titration
Incompatible Materials Oxidizing agents, Acid chlorides, Acid anhydrides, Reducing agents, Acids
Lower Explosion Limit 5.5 %(V)
Melting Point/Range -98 °C
Partition Coefficient No data available
Solubility in Water Completely miscible
Upper Explosion Limit 31 %(V)
Vapor Density No data available
Vapor Pressure 128 hPa (20 °C)
Viscosity No data available
pH-Value Neutral
Product Line Hydranal™
Storage Temperature Ambient

HYDRANAL™ – Titrant 5

HYDRANAL™ – Titrant 5 is a reagent used in Karl Fischer titration to determine the water content in a sample. This reagent contains iodine dissolved in alcohol, along with sulfur dioxide and imidazole in a solvent solution. More specifically, Titrant 5 is a volumetric two-component titration reagent, meaning it is used in combination with a compatible Karl Fischer solvent.

Karl Fischer Titration:

An analytical method used to determine the water content in various types of samples.

Composition of Titrant 5:

Titrant 5 contains iodine dissolved in alcohol, as well as sulfur dioxide and imidazole in a solvent.

Two-Component Reagent System:

HYDRANAL™ – Titrant 5 is part of a two-component titration system, which requires a separate solvent reagent (e.g., HYDRANAL™ – Solvent) to complete the titration process.

Solvents:

The solvents used in the HYDRANAL™ system can include:

  • Methanol (for standard reagents)

  • Ethanol (for E-type reagents)
    The choice of solvent depends on the type of sample being analyzed.

Applications:

HYDRANAL™ – Titrant 5 is widely used in analytical testing across industries such as chemicals, pharmaceuticals, and food, to ensure product quality and compliance.

‘

‘

CV. Andalan Prima Sejahtera Perumahan 
Bintang Metropol Jl. Jupiter VI Blok A7 No. 16 
Bekasi Utara, Kota Bekasi, Jawa Barat 17122 
Telepon  : 021-29253187, 021-29253186, 021-29253184 
No. WA   : +62 812-9077-3137, +62 813-1704-0860, +62 813-8249-1575 
Email    : andalan123@gmail.com, sales@cvaps.co.id 
Website  : cvaps.co.id